Bulletins

SIEMENS CERT
12/08/2020
A vulnerability was identified in LOGO! Soft Comfort. The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. Siemens has released an update for the LOGO! Soft Comfort and recommends that customers update to the latest version.
SIEMENS CERT
12/08/2020
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software …
SIEMENS CERT
12/08/2020
SCALANCE X switches, RUGGEDCOM Win, RFID 181EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client’s DHCP request. Siemens has released …
SIEMENS CERT
12/08/2020
The latest update for LOGO! 8 BM fixes multiple vulnerabilities. The most severe could allow an attacker with network access to gain full control over the device. Siemens has released updates for the affected products and recommends that customers update to the latest version.
SIEMENS CERT
12/08/2020
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative …
SIEMENS CERT
12/08/2020
A missing authentication vulnerability has been identified in SIEMENS LOGO!8 BM devices. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from the devices if the attacker has access to port 135/tcp.
SIEMENS CERT
12/08/2020
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …
SIEMENS CERT
12/08/2020
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …