Bulletins

SIEMENS CERT
08/13/2024
Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform …
SIEMENS CERT
08/13/2024
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set passwords from an embedded storage IC. Siemens has released new hardware versions with the LOGO! V8.4 BM product family for …
SIEMENS CERT
08/13/2024
Several Intel-CPU based SIMATIC IPCs are affected by an information exposure vulnerability (CVE-2022-40982) in the CPU that could allow an authenticated local user to potentially read other users’ data [1]. The issue is also known as “Gather Data Sampling” (GDS) or Downfall Attacks. For details refer to the chapter “Additional …
BOSCH PSIRT
08/07/2024

BOSCH-SA-587194-BT: DIVAR IP System Manager is a central user interface that provides an easy system setup, configuration and application software upgrades through an easily accessible web-based application. Multiple Curl vulnerabilities in the Git for Windows component have been discovered in DIVAR IP System Manager versions prior to 2.3.2, affecting several …

US CERT
08/02/2024
Executive Summary The Cybersecurity and Infrastructure Security Agency (CISA) conducted a red team assessment (RTA) at the request of a critical infrastructure organization. During RTAs, CISA’s red team simulates real-world malicious cyber operations to assess an organization’s cybersecurity detection and response capabilities. In coordination with the assessed organization, CISA is …
SIEMENS CERT
08/02/2024
Omnivise T3000 contains multiple vulnerabilities that could allow an attacker to escalate privileges. Siemens Energy has released patches for several affected products and recommends to apply the patches. Siemens Energy is preparing further fixes for versions still under maintenance and recommends countermeasures for products where fixes are not, or not …
SIEMENS CERT
07/22/2024
Multiple SICAM products are affected by unauthorized password reset and firmware downgrade vulnerabilities that could lead to privilege escalation and potential leak of information, namely: SICAM A8000 Device firmware CPCI85 for CP-8031/CP-8050 SICAM EGS Device firmware CPCI85 SICAM 8 Software Solution SICORE Siemens has released new firmware versions for the …
SIEMENS CERT
07/22/2024
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …