SIEMENS CERT
12/12/2023
The OPC UA implementations (ANSI C and C++) as used in several SIMATIC products contain a denial of service vulnerability that could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Siemens has released updates for several affected products and recommends …
SIEMENS CERT
12/12/2023
A Denial-of-Service vulnerability has been identified in LOGO! 8 BM. This vulnerability could allow an attacker to crash a device, if a user is tricked into loading a malicious project file onto an affected device. The vulnerability is related to the hardware of the product. Siemens has released new hardware …
SIEMENS CERT
12/12/2023
Several SIMATIC products are affected by a type confusion vulnerability relating to OpenSSL X.400 address processing (CVE-2023-0286), as disclosed disclosed on 2023-02-07 at https://www.openssl.org/news/secadv/20230207.txt. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for …
SIEMENS CERT
12/12/2023
Multiple vulnerabilities have been identified in the Linux Kernel of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
12/12/2023
Multiple vulnerabilities have been identified in the BIOS of the SIMATIC S7-1500 TM MFP V1.0. Siemens is preparing updates and recommends specific countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
12/12/2023
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed …
SIEMENS CERT
12/12/2023
Siemens has released a new version of STEP 7 (TIA Portal) that fixes an information disclosure vulnerability. A local attacker could gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application.
SIEMENS CERT
12/12/2023
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver to perform a denial of service attack. Siemens has released a new version for SINAMICS S120 (incl. SIPLUS variants) and recommends to update to the latest version. Siemens recommends specific countermeasures for products …